ADDITIVE FOR DIESEL FUEL “HELIOS 3D”
TECHNICAL SPECIFICATION 
CONFIRM ÑO-ORDINATED
PRESIDENT: Ministry of Health
/Boris Poptchev/ Letter ¹ 47-22- ÕÒ -00 456 / 28.02.2000 ã .
The technical specification concerns chemical additive for winter diesel fuel , which is a complex multifunctional system . Helios 3D is an additive for winter diesel fuel . Helios 3D takes part in the crystallization process of paraffin disturbing their structure. In this way it is hampered the increase of crystals, which lower the mobility of the fuel. As a result the border temperature of filtration of diesel fuel is considerably decreased and it is ensured fuel’s exploitation in winter conditions without problems.
Helios 3D improves the incineration of diesel fuel and by this way accelerating burning process, increases full burning out and contributes to burning out of the solid particles in the fuming gases . The quantity of the CO and not burned hydrocarbons is decreased and affects positively over the reduction of fuel consumption.
1. QUALITATIVE REQUIREMENTS
INDEX NORM
1. Appearance Not transparent liquid
2. Colour pale yellow
3 . Density in 15 î Ñ, g/ñì3 it determines
5. Fractional composition :
- beginning boiling temperature , ° Ñ not lower than 28
- 10% distillate under the temperature ° Ñ not lower than 51
- 50% distillate under the temperature ° Ñ not lower than 83

2. REGULATIONS OF ACCEPTANCE AND METHOD OF SAMPLING
According to Bulgarian State Standard / BSS/ ISO 3170
3. TESTING METHODS
3.1. Appearance
It determines visual in daylight
3.2. Colour
It determines visual in daylight
3. 3 . Density in 15° Ñ
According BSS EN ISO 3675 -98
3.4. Fractional composition
According BSS ISO 3405 -98
4.ÒÅCHICS OF SAFETY AND SANITARY HYGIENIC REQUIREMENTS
1. The production of CSLF HELIOS 3 D belongs to the category A in fire safety which is obvious from a Record N 145 / 95, page 2 from RB of the Ministry of Internal Affairs – NIIPO Sofia /.
The storage of the ready product is organized in accordance with the fire safety rules in the chemical industry.
2. If the burning liquids are spilled immediately clean with wood saw-dust and thoroughly wash with water
3. Smoking and bringing fire in the workshop and in the storehouse is forbidden.
4. In case of fire use chemical foam, gas and powder fire-extinguishing components , carbon dioxide.
5. Workers are in working clothes and rubber gloves when they use the supplement HELIOS 3 D.
6. If the product fall on the skin, wash thoroughly with water and soap the affected spots. If it fall in the eyes – the same procedure during 15 minutes
- CONDITIONS OF SAFE-KEEPING
The additive should be stored according all firefighting regulations at dry and ventilated place, at temperature 5-15 0C.
|